Home / Liquid Pumps / Progressive Cavity Pumps / Method of Operation  
   
 

Bornemann progressive cavity pumps consist of only one moving part - a driven metal (inelastic) rotor, rotating within an elastomer lined (elastic) stator. As the rotor turns, chambers are formed between the rotor and stator. These chambers progress axially from the suction to discharge end, moving the fluid.

   

By increasing the pitch of the rotor and stator, additional chambers or stages are formed. The design allows pumping in both directions, a high suction lift and cautious pumping. Due to the numerous combinations of material for rotor and stator and the cautious pumping with extremely low shear forces, the progressive cavity pumps are also highly suitable for measuring and metering tasks.

 

   
Deutsch / English  
Download:
Brochure Progressive Cavity Pumps
PDF (362 kb)
 
 
  Copyright 2001-2008 by Joh. Heinr. Bornemann GmbH · Industriestraße 2 · 31683 Obernkirchen Designed and coached by net-lions